Product Design, Manufacturing & Innovation Resources
بيت » Implantable Cardioverter-Defibrillator (ICD)

Implantable Cardioverter-Defibrillator (ICD)

1980
  • Michel Mirowski
  • Morton Mower
Implantable cardioverter-defibrillator device in a surgical setting, biomedical engineering.

(صورة توضيحية فقط)

An implantable cardioverter-defibrillator (ICD) is a small, battery-powered device placed in the chest to monitor heart rhythm and detect life-threatening arrhythmias like ventricular tachycardia or fibrillation. When an abnormal rhythm is detected, the ICD can deliver a precisely calibrated electrical shock (defibrillation) to restore a normal heartbeat, preventing sudden cardiac death.

يتكون نظام مقوم نظم القلب ومزيل الرجفان القابل للزرع (ICD) من مولد نبضات وسلك أو أكثر من الأقطاب الكهربائية. يُزرع المولد، الذي يحتوي على بطارية ودائرة إلكترونية، عادةً تحت الجلد أسفل عظمة الترقوة. أما الأقطاب فهي أسلاك رفيعة معزولة تُمرر عبر وريد إلى حجرات القلب. تحتوي هذه الأقطاب على أقطاب كهربائية في أطرافها تراقب النشاط الكهربائي للقلب (تعمل كجهاز تخطيط كهربية القلب) ويمكنها أيضًا إرسال نبضات كهربائية. يحلل الجهاز إيقاع القلب باستمرار. إذا اكتشف إيقاعًا سريعًا جدًا أو غير منتظم (تسرع القلب أو الرجفان)، فإنه يحاول أولاً تصحيحه بسلسلة من النبضات الكهربائية منخفضة الطاقة، وهي عملية تسمى تنظيم ضربات القلب المضاد لتسرع القلب (ATP). إذا لم ينجح تنظيم ضربات القلب المضاد لتسرع القلب أو إذا كان اضطراب النظم يهدد الحياة بشكل فوري (مثل الرجفان البطيني)، يقوم جهاز مقوم نظم القلب ومزيل الرجفان القابل للزرع بشحن مكثفاته وإرسال نبضة كهربائية. طاقة عالية تُستخدم الصدمات الكهربائية لإعادة ضبط القلب. كما تعمل أجهزة تنظيم ضربات القلب الحديثة كمنظمات لضربات القلب، حيث توفر تحفيزًا كهربائيًا في حال انخفاض معدل ضربات القلب (بطء القلب). وتتميز هذه الأجهزة أيضًا بقدرات متطورة لتسجيل البيانات، حيث تسجل اضطرابات النظم القلبي ليراجعها طبيب القلب لاحقًا، مما يساعد في تحسين علاج المريض.

UNESCO Nomenclature: 3201
– Biomedical engineering

يكتب

Physical Device

خلل

Revolutionary

الاستخدام

استخدام واسع النطاق

مقدمات

  • invention of the external defibrillator by claude beck in 1947
  • development of the implantable pacemaker in the 1950s
  • advances in transistor and battery technology
  • understanding of the electrophysiology of cardiac arrhythmias

التطبيقات

  • prevention of sudden cardiac death in high-risk patients
  • treatment for survivors of cardiac arrest due to ventricular fibrillation
  • management of certain congenital heart conditions
  • therapy for patients with advanced heart failure and low ejection fraction

براءات الاختراع:

  • US4202340A

أفكار ابتكارية محتملة

  • subcutaneous icds (s-icd) with leads placed under the skin, not in the heart
  • leadless pacemakers and icds that are self-contained within the heart
  • icds with bluetooth connectivity for remote monitoring via smartphone apps
  • mri-conditional icds that are safe for use in magnetic resonance imaging scanners
  • icds with advanced algorithms to better discriminate between dangerous and benign arrhythmias
  • energy-harvesting icds powered by the motion of the heart itself
  • icds integrated with sensors to monitor physiological parameters like heart failure status
  • biological pacemakers using gene therapy as an alternative to electronic devices
  • miniaturized icds with significantly longer battery life
  • ai-driven predictive analytics to forecast arrhythmic events based on icd data
Related to: ICD, implantable cardioverter-defibrillator, arrhythmia, ventricular fibrillation, sudden cardiac death, defibrillation, pacemaker, tachycardia, michel mirowski, cardiology.

السياق التاريخي

Implantable Cardioverter-Defibrillator (ICD)

1960
1969
1976-05-28
1980
1990
1960
1965
1970
1980
1980
1990

(إذا كان التاريخ غير معروف أو غير ذي صلة، على سبيل المثال "ميكانيكا الموائع"، يتم توفير تقدير تقريبي لظهوره الملحوظ)

أحدث الإضافات

أهم المنشورات والمقالات

أفضل الأدوات الأصلية

السنة العاشرة عيد