Casa » Sterility Assurance Level (SAL)

Sterility Assurance Level (SAL)

1970
Laboratory sterility testing for medical devices in applied microbiology.

SAL is a quantitative measure representing the probability of a single viable microorganism surviving on an item after sterilization. A commonly required SAL for medical devices is [latex]10^{-6}[/latex], meaning a one-in-a-million chance of a non-sterile unit. This probabilistic approach acknowledges that absolute sterility cannot be proven, only inferred statistically from convalida del processo.

The concept of the Sterility Assurance Level (SAL) is rooted in the understanding that microbial death follows first-order kinetics, meaning it is a probabilistic event. It is impossible to prove that every single microorganism on an object has been killed; one can only calculate the probability of a microbe surviving the process. The SAL is this probability. For instance, an SAL of [latex]10^{-6}[/latex] does not mean one contaminated item exists for every million produced. Instead, it means there is a one-in-a-million chance for any given item to harbor a single viable microorganism after the sterilization process. This statistical approach is fundamental to the convalida of sterilization cycles in regulated industries like pharmaceuticals and medical devices. To establish a cycle that achieves a desired SAL, manufacturers perform validation studies. This often involves placing biological indicators (BIs), which are standardized preparations of highly resistant bacterial spores (like Geobacillus stearothermophilus for steam or Bacillus atrophaeus for EtO), in the most challenging locations within a sterilization load. The process parameters (e.g., time, temperature, concentration) are then adjusted and tested until they consistently achieve a complete kill of the BIs. The cycle is then extended for a ‘half-cycle’ or more to provide a safety margin, ensuring the process can deliver the target SAL of [latex]10^{-6}[/latex] or better. The choice of SAL depends on the intended use of the product. Items that will come into contact with compromised tissue, such as surgical implants and injectable drugs, require the most stringent SAL of [latex]10^{-6}[/latex]. For items that contact intact skin, a lower SAL of [latex]10^{-3}[/latex] may be acceptable.

The formalization of SAL as a regulatory standard emerged in the latter half of the 20th century, driven by agencies like the U.S. Food and Drug Administration (FDA) and international standards organizations (ISO). Before this, sterility was often treated as an absolute state—an item was either sterile or not. However, as manufacturing scaled up and the risks of contamination became better understood, a more rigorous, quantitative struttura was needed. This shift from a qualitative to a probabilistic definition of sterility was a major advancement. It provided a scientific and defensible basis for process validation, allowing manufacturers to demonstrate the effectiveness and reproducibility of their sterilization methods to regulators and ensuring a consistent level of safety for patients.

UNESCO Nomenclature: 2401
– Microbiology

Tipo

Quantitative Metric

Disruption

Substantial

Utilizzo

Widespread Use

Precursors

Applicazioni

  • validation of sterilization cycles for medical devices
  • regulatory approval for pharmaceutical products
  • quality control in food processing
  • aseptic manufacturing in biotechnology

Brevetti:

QUELLO

Potential Innovations Ideas

Livelli! Iscrizione richiesta

Per accedere a questo contenuto devi essere un membro di !Professionals (100% free)!

Iscriviti ora

Siete già membri? Accedi
Related to: SAL, sterility assurance level, probability, microbiology, validation, medical devices, pharmaceuticals, FDA, ISO, biological indicators.

Lascia un commento

Il tuo indirizzo email non sarà pubblicato. I campi obbligatori sono contrassegnati *

DISPONIBILE PER NUOVE SFIDE
Mechanical Engineer, Project, Process Engineering or R&D Manager
Sviluppo efficace del prodotto

Disponibile per una nuova sfida con breve preavviso.
Contattami su LinkedIn
Plastic metal electronics integration, Design-to-cost, GMP, Ergonomics, Medium to high-volume devices & consumables, Lean Manufacturing, Regulated industries, CE & FDA, CAD, Solidworks, Lean Sigma Black Belt, medical ISO 13485

Stiamo cercando un nuovo sponsor

 

La tua azienda o istituzione si occupa di tecnica, scienza o ricerca?
> inviaci un messaggio <

Ricevi tutti i nuovi articoli
Gratuito, no spam, email non distribuita né rivenduta

oppure puoi ottenere la tua iscrizione completa -gratuitamente- per accedere a tutti i contenuti riservati >Qui<

Historical Context

(if date is unknown or not relevant, e.g. "fluid mechanics", a rounded estimation of its notable emergence is provided)

Related Invention, Innovation & Technical Principles

Torna in alto

Potrebbe anche piacerti