بيت » US Fire Classification System (NFPA 10)

US Fire Classification System (NFPA 10)

1950
  • National Fire Protection Association (NFPA)
Fire extinguisher display categorized by US Fire Classification System for safety compliance.

The United States fire classification system, standardized by NFPA 10, categorizes fires into five main classes based on the type of fuel. Class A includes ordinary combustibles like wood and paper. Class B covers flammable liquids and gases. Class C is for fires involving energized electrical equipment. Class D pertains to combustible metals, and Class K is for cooking oils and fats.

The NFPA 10 standard provides a foundational نطاق for fire safety in the United States. Its primary purpose is to simplify the selection of the correct extinguishing agent for a given fire, preventing the user from inadvertently making the situation worse. For example, using a water-based (Class A) extinguisher on a flammable liquid fire (Class B) could spread the burning fuel, and using it on an electrical fire (Class C) could lead to electrocution.

Each class corresponds to specific extinguishing methods. Class A fires are typically extinguished by the cooling effect of water or by smothering with dry chemicals. Class B fires require agents that cut off the oxygen supply, such as carbon dioxide, dry chemical, or foam. Class C fires require a non-conductive agent like carbon dioxide or a dry chemical; the primary goal is to de-energize the circuit before tackling the fire as a Class A or B. Class D fires need special dry powder agents that smother the fire without reacting with the burning metal. Class K, established in 1998 for commercial kitchens, uses wet chemical agents that cool the fire and produce a soapy foam layer (saponification) to prevent re-ignition of hot grease.

This classification system is visually represented by pictograms on fire extinguishers—a green triangle for A, a red square for B, a blue circle for C, a yellow star for D, and a black hexagon for K—making identification quick and intuitive during an emergency.

UNESCO Nomenclature: 3305
- الهندسة الكيميائية

النوع

النظام التجريدي

الاضطراب

التأسيسية

الاستخدام

الاستخدام الواسع النطاق

السلائف

  • ال fire triangle concept (fuel, heat, oxygen)
  • empirical knowledge of different materials’ combustion properties
  • development of early extinguishing agents like water, sand, and soda-acid
  • increased fire risks from industrialization and electrification

التطبيقات

  • design and labeling of portable fire extinguishers
  • development of building fire codes and اللوائح
  • firefighter training and emergency response protocols
  • specification of automatic fire suppression systems (e.g., sprinklers)
  • workplace safety requirements mandated by osha

براءات الاختراع:

NA

أفكار ابتكارات محتملة

!!مستويات !!! العضوية مطلوبة

يجب أن تكون عضوًا !!! مستويات!!! للوصول إلى هذا المحتوى.

انضم الآن

هل أنت عضو بالفعل؟ سجّل الدخول هنا
Related to: NFPA 10, fire classification, class A, class B, class C, class D, class K, fire safety, fire extinguisher, USA.

اترك تعليقاً

لن يتم نشر عنوان بريدك الإلكتروني. الحقول الإلزامية مشار إليها بـ *

متاح للتحديات الجديدة
مهندس ميكانيكي، مشروع، هندسة العمليات أو مدير البحث والتطوير
تطوير المنتج الفعال

متاح لتحدي جديد في غضون مهلة قصيرة.
تواصل معي على LinkedIn
تكامل الإلكترونيات المعدنية والبلاستيكية، التصميم مقابل التكلفة، ممارسات التصنيع الجيدة (GMP)، بيئة العمل، الأجهزة والمواد الاستهلاكية متوسطة إلى عالية الحجم، التصنيع المرن، الصناعات الخاضعة للتنظيم، شهادات CE وFDA، التصميم بمساعدة الحاسوب (CAD)، Solidworks، الحزام الأسود من Lean Sigma، شهادة ISO 13485 الطبية

نحن نبحث عن راعي جديد

 

هل شركتك أو مؤسستك متخصصة في التقنية أو العلوم أو الأبحاث؟
> أرسل لنا رسالة <

احصل على جميع المقالات الجديدة
مجاني، لا يوجد بريد عشوائي، ولا يتم توزيع البريد الإلكتروني ولا إعادة بيعه

أو يمكنك الحصول على عضويتك الكاملة -مجانًا- للوصول إلى جميع المحتويات المحظورة >هنا<

الاختراع والابتكار والمبادئ التقنية ذات الصلة

انتقل إلى الأعلى

قد يعجبك أيضاً