The Effectiveness-NTU método is used in heat exchanger analysis when fluid inlet temperatures are known, but outlet temperatures are not. Effectiveness ([latex]\epsilon[/latex]) is the ratio of actual heat transfer to the maximum possible heat transfer. The Number of Transfer Units (NTU) is a dimensionless measure of the heat exchanger’s size, defined as [latex]NTU = \frac{UA}{C_{min}}[/latex].

The Effectiveness-NTU method provides a powerful alternative to the LMTD method, especially in situations where iterating to find outlet temperatures would be cumbersome. The core of the method lies in three dimensionless parameters: effectiveness ([latex]\epsilon[/latex]), the number of transfer units (NTU), and the heat capacity rate ratio ([latex]C_r = C_{min}/C_{max}[/latex]). The maximum possible heat transfer rate, [latex]Q_{max}[/latex], occurs in a hypothetical infinitely long counter-flow heat exchanger, where the fluid with the smaller heat capacity rate ([latex]C_{min}[/latex]) undergoes the maximum possible temperature change, [latex]\Delta T_{max} = T_{h,in} – T_{c,in}[/latex]. Thus, [latex]Q_{max} = C_{min}(T_{h,in} – T_{c,in})[/latex]. The actual heat transfer is then simply [latex]Q = \epsilon Q_{max}[/latex]. The key is that effectiveness ([latex]\epsilon[/latex]) can be expressed as a function of only NTU and [latex]C_r[/latex] for a given flow arrangement. For example, for a parallel-flow exchanger, the relationship is [latex]\epsilon = \frac{1 – \exp[-NTU(1+C_r)]}{1+C_r}[/latex]. These relationships have been derived and charted for numerous common heat exchanger configurations, allowing engineers to quickly determine the performance of a given exchanger or to size a new one without knowing the outlet temperatures beforehand. This method is particularly useful in design and optimization studies where the impact of changing the exchanger’s size (and thus NTU) on its performance (effectiveness) is being investigated.

UNESCO Nomenclature: 3328
Termodinâmica

Tipo

Sistema abstrato

Interrupção

Incremental

Uso

Uso generalizado

Precursores

  • Método LMTD para análise de trocadores de calor
  • concept of dimensionless numbers in fluid mechanics and heat transfer (e.g., reynolds, prandtl numbers)
  • avanços na termodinâmica e na dinâmica dos fluidos durante o início do século XX

Aplicações

  • análise de regeneradores de turbinas a gás
  • Projeto de trocadores de calor compactos onde as temperaturas de saída são difíceis de prever.
  • Avaliação do desempenho de sistemas de refrigeração eletrônica
  • design de radiador automotivo
  • sistemas de gerenciamento térmico aeroespacial

Patentes:

NA

Ideias de Inovação Potencial

Devido ao tráfego de bots de coleta de dados, atualmente superior a 40 mil por dia, este conteúdo é reservado aos membros da comunidade.
> Login < ou > Registrar < (100% gratuito) para acessar isso, assim como todo o restante do conteúdo e das ferramentas restritas.

Relacionado a: eficácia, NTU, trocador de calor, transferência de calor, Kays e London, termodinâmica, número adimensional, projeto térmico, trocador de calor compacto, relação de taxa de capacidade.

Contexto histórico

Eficácia - Método NTU

1950
1950
1950
1955
1958
1960
1960
1950
1950
1950
1955
1956
1960
1960
1960

(Caso a data seja desconhecida ou irrelevante, por exemplo, "mecânica dos fluidos", é fornecida uma estimativa aproximada de seu surgimento notável)

Princípios relacionados à invenção, inovação e tecnologia

Imagens em tamanho real e downloads estão disponíveis apenas, 100% gratuitos, para membros registrados.